Systemic Carbon Dioxide Detector SC-CO

Liên hệ

Mã sản phẩm
SC-CO/*2*
Mô tả

Origin: Poland. Measuring ranges: 0 ÷ 1000 ppm CO

Khuyến mãi

Contact: +84 904544588

Số lượng

Systemic carbon oxide detector SC-CO/*2* is a device intended for continuous measurement of carbon oxide concentration in the range 0-200 ppm or 0-1000 ppm CO (or less on demand) and designed to measure gas content in the atmosphere of the mine.It is suitable for use with gas detection systems or as stand alone device monitoring parameters of underground mines and surface areas where is possibility of explosion of methane or coal dust.

Ouput signal from the detectors can be, depending on the version:

- Digital signal FSK;

- Voltage signal 0,4 ÷ 2 V or 1÷ 5 V;

- Current signal 4 ÷ 20 mA(passive);

- Frequency coded 5 ÷ 12 kHz.

Detector operates in one of following transmission configuration (depending on version):

- FSK with voltage signal;

- Frequency coded with voltage signal;

- FSK with passive current signal;

- Frequency coded with passive current signal.

SC-CO/*2* detector can operate in the stand-alone mode and then is supplied from intrinsically safe power supply unit.

The detector is also performing the function of two thresholds switch-off device, allowing control of external devices via 2 (galvanically isolated) two-state outputs. The detector is also fitted with 2 two-state inputs which can be used for confirmation of switching-off an external device.

Two alarm thresholds can be set to specific values in the range 0 ÷ 26 ppm CO.

Exceeding of given alarm threshold causes activation of alarm as a red diode (version SC-CO/*2L) or buzzer (version SC-CO/*2S) and change of given detector`s output (s). Green LED on the front informs about proper operation of the device.

Power supply

From intrinsically safe telemetric line Ui=60 V, Ii = 150 mA

From intrinsically safe power supply unit  U= 15 V; I = approx. 35 mA

Versions

* i - current output (passive)

  S - buzzer alarm 

  L - LED alarm

  Si - buzzer and current output or outputs

  Li - LED signaling device and current output or outputs

SC-CO/n2* - Basic version

SC-CO/s2* - Special version - modified software, other measuring range

Output signal

Frequency 5 ÷ 12 kHz

Digital FSK

Voltage  0,4 ÷ 2 V  or  1 ÷ 5 V

Current  4 ÷ 20 mA (passive)

Principle of operation – Diffusion penetration of gas to the cylinder head

Electrochemical sensor

Measuring ranges

0 ÷ 200 ppm CO (for version SC-CO/n2*)

0 ÷ 1000 ppm CO or less on demand (for version  SC-CO/s2*)

Accuracy SC-CO/*2*

± 3 ppm for the range  0 ÷ 100 ppm CO

± 5 ppm for the range  100 ÷ 200 ppm CO

± 5 ppm for the range  100 ÷ 200 ppm CO

Resolution

1 ppm

Measurement method

Continuous

Response time T90

≤ 20 sec.

Air flow rate

Up to 10 m/s

Humidity

< 95 % without condensation

Dustiness of the air

max 1000 mg/m3

Impacts and vibrations

Not permissible

Ambient temperature and temperature of measured gas mixture

-20 ≤ T ≤ 50 oC

Protection level

 I M1 Ex ia I Ma

Delay of alarm threshold relays AL1, AL2

< 1 sec.

IP rating

IP54

Dimensions

175 × 80 × 90 mm

Weight

0,9 kg

Power supply

From intrinsically safe telemetric line Ui=60 V, Ii = 150 mA

From intrinsically safe power supply unit  U= 15 V; I = approx. 35 mA

Versions

* i - current output (passive)

  S - buzzer alarm 

  L - LED alarm

  Si - buzzer and current output or outputs

  Li - LED signaling device and current output or outputs

SC-CO/n2* - Basic version

SC-CO/s2* - Special version - modified software, other measuring range

Output signal

Frequency 5 ÷ 12 kHz

Digital FSK

Voltage  0,4 ÷ 2 V  or  1 ÷ 5 V

Current  4 ÷ 20 mA (passive)

Principle of operation – Diffusion penetration of gas to the cylinder head

Electrochemical sensor

Measuring ranges

0 ÷ 200 ppm CO (for version SC-CO/n2*)

0 ÷ 1000 ppm CO or less on demand (for version  SC-CO/s2*)

Accuracy SC-CO/*2*

± 3 ppm for the range  0 ÷ 100 ppm CO

± 5 ppm for the range  100 ÷ 200 ppm CO

± 5 ppm for the range  100 ÷ 200 ppm CO

Resolution

1 ppm

Measurement method

Continuous

Response time T90

≤ 20 sec.

Air flow rate

Up to 10 m/s

Humidity

< 95 % without condensation

Dustiness of the air

max 1000 mg/m3

Impacts and vibrations

Not permissible

Ambient temperature and temperature of measured gas mixture

-20 ≤ T ≤ 50 oC

Protection level

 I M1 Ex ia I Ma

Delay of alarm threshold relays AL1, AL2

< 1 sec.

IP rating

IP54

Dimensions

175 × 80 × 90 mm

Weight

0,9 k

Nội dung đang được cập nhật
Nội dung đang được cập nhật
Chi tiết sản phẩm

Systemic carbon oxide detector SC-CO/*2* is a device intended for continuous measurement of carbon oxide concentration in the range 0-200 ppm or 0-1000 ppm CO (or less on demand) and designed to measure gas content in the atmosphere of the mine.It is suitable for use with gas detection systems or as stand alone device monitoring parameters of underground mines and surface areas where is possibility of explosion of methane or coal dust.

Ouput signal from the detectors can be, depending on the version:

- Digital signal FSK;

- Voltage signal 0,4 ÷ 2 V or 1÷ 5 V;

- Current signal 4 ÷ 20 mA(passive);

- Frequency coded 5 ÷ 12 kHz.

Detector operates in one of following transmission configuration (depending on version):

- FSK with voltage signal;

- Frequency coded with voltage signal;

- FSK with passive current signal;

- Frequency coded with passive current signal.

SC-CO/*2* detector can operate in the stand-alone mode and then is supplied from intrinsically safe power supply unit.

The detector is also performing the function of two thresholds switch-off device, allowing control of external devices via 2 (galvanically isolated) two-state outputs. The detector is also fitted with 2 two-state inputs which can be used for confirmation of switching-off an external device.

Two alarm thresholds can be set to specific values in the range 0 ÷ 26 ppm CO.

Exceeding of given alarm threshold causes activation of alarm as a red diode (version SC-CO/*2L) or buzzer (version SC-CO/*2S) and change of given detector`s output (s). Green LED on the front informs about proper operation of the device.